Page 49 - HUB-4 Magazine Issue 100
P. 49
Quarrying News
without supporting documentation. These terms should be
backed by measurable properties and evidence relevant to the
finished product.
Purchasers should ask the manufacturer to confirm:
• The specified concrete strength
• The product’s dimensions and declared weight
• The materials used in its manufacture
• The manufacturing and quality-control procedures
• Relevant test results and technical documentation
• The standards or specifications to which the product is
manufactured
• Any limitations affecting its use
Concrete products should be purchased on evidence, not
appearance or assumption.
Fire performance must be demonstrated
Fire is an increasingly important consideration for quarry,
waste, recycling and materials-processing sites.
Combustible waste, fuel, oils, tyres, batteries and machinery
can create a substantial fire load. Lithium-ion batteries
entering waste and recycling streams present a particular
challenge because damaged or defective batteries can ignite
rapidly and may be difficult to extinguish.
Concrete is inherently non-combustible and can provide
valuable passive fire protection. However, stakeholders should
not assume that every product described as a concrete block
automatically carries the same fire classification or will
perform identically in a fire.
The composition of the finished product matters.
Manufacturers making claims about reaction-to-fire
performance should be able to provide evidence supporting
those claims, including the applicable classification and the
basis on which it has been achieved.
For example, Owen continues, Elite Precast Concrete’s
Legato® interlocking blocks are classified as Class A1 in
accordance with the relevant provisions of BS EN 13369. This
provides specifiers and site operators with clear, documented
information rather than an unsupported statement that the
product is simply “fireproof” or “fire-resistant”.
It is also important to distinguish between reaction to fire and
fire resistance. A reaction-to-fire classification considers how a
product contributes to the development and spread of fire. Fire
resistance relates to the ability of a complete element or
structure to maintain functions such as integrity, insulation or
loadbearing capacity for a stated period.
A non-combustible block does not, by itself, establish a fire-
resistance period for every wall configuration. The design,
joints, height, layout and intended function of the completed
structure must all be considered.
Non-conforming products create shared risks
The consequences of installing an unsuitable or non-
conforming product can extend far beyond the original
purchasing decision.
A wall failure could result in injury, damage to machinery,
contamination of materials, production delays and costly
reconstruction. In a fire, an inadequately specified product or
structure could fail to provide the anticipated level of
containment, increasing the potential for fire to spread to
neighbouring stockpiles, equipment or buildings.
There may also be insurance, contractual and regulatory
implications if products cannot be traced or if performance
claims are unsupported.
Responsibility does not rest solely with the manufacturer.
Specifiers, distributors, contractors, installers and end users all
have a part to play in ensuring that products are appropriate
for their intended use.
Procurement teams must understand that accepting an
alternative product is not simply a commercial substitution. If
the alternative has different structural properties, fire
performance or technical limitations, the original design may
no longer be valid.
Likewise, contractors should not change block types, layouts or
wall heights without confirming the implications with the
relevant designer or supplier.
Traceability provides confidence
A reputable manufacturer should be able to trace its products
to controlled production processes and provide clear technical
data.
Traceability becomes particularly important when investigating
defects, confirming product performance or demonstrating
that the correct materials were supplied. Products
manufactured from unidentified or poorly controlled sources
may be difficult to verify once they have arrived on site.
Quarry operators and contractors should retain product data
sheets, delivery records, design information, installation
drawings and relevant declarations or certificates as part of
the project file.
These records provide evidence that reasonable checks were
undertaken and help ensure that future site teams understand
what has been installed and how it should be used.
Communicate requirements throughout the
supply chain
Good product selection depends on clear communication. The
designer may understand the loads acting on a storage wall,
but this information must reach the procurement team. The
manufacturer may specify a maximum wall height, but that
information must reach the installer and site operator. The
purchasing team may agree to a substitute product, but the
designer must be given the opportunity to assess it.
All stakeholders should understand:
• What the structure has been designed to contain or retain
• The maximum permitted height
www.hub-4.com Sept/Oct - Issue 100
| p49 |